2017 NFPA 502 Standard - Current Edition

Build your own set and Save 15%. NFPA Members save an additional 10%.

Item #: NFPA_502
Price: $0.00
Edition:
Formats Available:












Quantity:
  • Description

    NFPA 502 revisions and a new mandate for integrated testing help you improve the fire protection and life safety of today's road tunnels and bridges.

    From emergency egress to communications issues, limited-access highways, tunnels, bridges, elevated highways, and air right structures present a host of unique fire protection and life safety challenges. The 2017 edition of NFPA 502: Standard for Road Tunnels, Bridges, and Other Limited Access Highways provides designers, engineers, AHJs, and state and federal regulators with the latest guidelines for the construction, operation, maintenance, and fire protection of these venues to mitigate hazards, maintain structural integrity, and protect lives.

    This important international Standard also covers traffic control, standpipe and water supply, control of hazardous materials, emergency ventilation, electrical systems, and emergency response.

    Designers, engineers, architects, and AHJs will work more confidently to address risks and implement appropriate safety systems with this edition.

    • Added guidance for conducting an engineering analysis includes a revised list of considerations to be taken into account, along with more guidance in the Annexes.
    • Integrated testing on fire protection, life safety, and emergency systems is now required in accordance with NFPA 4: Standard for Integrated Fire Protection and Life Safety System Testing.
    • Modified requirements for the structural protection of bridges will assist designers, engineers, architects, and AHJs.
    • Annex B includes guidance on establishing noise levels in order to maintain a minimum level of speech intelligibility through the emergency communication system.
    • The constant K1 used in the critical velocity equation of Annex D has been modified and is no longer a constant for heat release rates (HRR) less than or equal to 100 MW.
    • Annex E presents new information regarding the effects of fire suppression on HRR and tunnel ventilation.
    • New Annex M adds guidance on the use of automatic fire detection systems in road tunnels.

    Apply the latest requirements to safeguard the public on limited-access highways, road tunnels, and bridges. (Softbound, 72 pp., 2017)

     

    Interested in other editions of NFPA 502? Use the drop down menu above to select the edition year you need.

  • Table of Contents (2017 Current Edition)

    NFPA® 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways, 2017 Edition

    Chapter 1 Administration
    1.1 Scope.
    1.2 Purpose.
    1.3 Application.
    1.4 Retroactivity.
    1.5 Equivalency.
    1.6 Units.
    Chapter 2 Referenced Publications
    2.1 General.
    2.2 NFPA Publications.
    2.3 Other Publications.
    2.4 References for Extracts in Mandatory Sections.
    Chapter 3 Definitions
    3.1 General.
    3.2 NFPA Official Definitions.
    3.3 General Definitions.
    Chapter 4 General Requirements
    4.1 Characteristics of Fire Protection.
    4.2 Safeguards During Construction.
    4.3 Fire Protection and Fire Life Safety Factors.
    4.4 Emergency Response Plan.
    4.5 Emergency Communications.
    4.6 Signage.
    4.7 Commissioning and Integrated Testing.
    4.8 Noncombustible Material.
    4.9 Structural Anchorage.
    Chapter 5 Limited Access Highways
    5.1 General.
    5.2 Traffic Control.
    5.3 Fire Apparatus.
    5.4 Protection of Structural Elements.
    5.5 Incident Detection. (Reserved)
    5.6 Fire Hydrants. (Reserved)
    5.7 Drainage.
    Chapter 6 Bridges and Elevated Highways
    6.1 General.
    6.2 Application.
    6.3 Protection of Structural Elements.
    6.4 Incident Detection.
    6.5 Traffic Control.
    6.6 Standpipe, Fire Hydrants, and Water Supply.
    6.7 Portable Fire Extinguishers.
    6.8 Drainage.
    6.9 Hazardous Locations.
    6.10 Control of Hazardous Materials.
    Chapter 7 Road Tunnels
    7.1 General.
    7.2 Application.
    7.3 Protection of Structural Elements.
    7.4 Fire Alarm and Detection.
    7.5 Emergency Communications Systems - Two-Way Radio Communication Enhancement System.
    7.6 Tunnel Closure and Traffic Control.
    7.7 Fire Apparatus.
    7.8 Standpipe, Fire Hydrants, and Water Supply.
    7.9 Portable Fire Extinguishers.
    7.10 Fixed Water-Based Fire-Fighting Systems.
    7.11 Emergency Ventilation.
    7.12 Tunnel Drainage System.
    7.13 Alternative Fuels.
    7.14 Control of Hazardous Materials.
    7.15 Flammable and Combustible Environmental Hazards.
    7.16 Means of Egress.
    7.17 Acceptance Test.
    Chapter 8 Roadways Beneath Air-Right Structures
    8.1 General.
    8.2 Application.
    8.3 Traffic Control.
    8.4 Protection of Structure.
    8.5 Emergency Ventilation.
    8.6 Drainage System.
    8.7 Control of Hazardous Materials.
    8.8 Emergency Response Plan.
    8.9 Standpipe, Fire Hydrants, and Water Supply.
    8.10 Acceptance Test.
    Chapter 9 Fixed Water-Based Fire-Fighting Systems
    9.1 General.
    9.2 Design Objectives.
    9.3 Performance Evaluation.
    9.4 Tunnel Parameters.
    9.5 System Design and Installation Documentation.
    9.6 Engineering Design Requirements.
    Chapter 10 Standpipe and Water Supply
    10.1 Standpipe Systems.
    10.2 Water Supply.
    10.3 Fire Department Connections.
    10.4 Hose Connections.
    10.5 Fire Pumps.
    10.6 Identification Signs.
    Chapter 11 Emergency Ventilation
    11.1 General.
    11.2 Smoke Control.
    11.3 Design Objectives.
    11.4 Basis of Design.
    11.5 Fans.
    11.6 Dampers.
    11.7 Sound Attenuators.
    11.8 Controls.
    11.9 Flammable and Combustible Liquids Intrusion.
    Chapter 12 Electrical Systems
    12.1 General.
    12.2 Wiring Methods.
    12.3 Installation Methods.
    12.4 Emergency Power.
    12.5 Reliability.
    12.6 Emergency Lighting.
    12.7 Security Plan.
    Chapter 13 Emergency Response
    13.1 General.
    13.2 Emergency Incidents.
    13.3 Emergency Response Plan.
    13.4 Participating Agencies.
    13.5 Operations Control Center (OCC).
    13.6 Liaisons.
    13.7 Emergency.
    13.8 Training, Exercises, Drills, and Critiques.
    13.9 Records.
    Chapter 14 Regulated and Unregulated Cargoes
    14.1 General.
    Chapter 15 Periodic Testing
    15.1 Periodic Testing.
    Annex A Explanatory Material
    Annex B Tenable Environment
    Annex C Temperature and Velocity Criteria
    Annex D Critical Velocity Calculations
    Annex E Fixed Water-Based Systems in Road Tunnels
    Annex F Emergency Response Plan Outline
    Annex G Alternative Fuels
    Annex H The Memorial Tunnel Fire Ventilation Test Program
    Annex I Tunnel Ventilation System Concepts
    Annex J Control of Road Tunnel Emergency Ventilation Systems
    Annex K Fire Apparatus
    Annex L Motorist Education
    Annex M Automatic Fire Detection Systems
    Annex N Informational References
  • NFPA eBooks and PDFs

    NFPA® eBooks and PDFs can be downloaded immediately after purchase for quick, easy access.

    Accessing
    Upon purchase of an NFPA eBook or PDF, you will be prompted with instructions for downloading and accessing.