  • Description

    Protect openings in rated walls, floors, and ceilings against the spread of fire and smoke with NFPA 80.

    Expanded, revised, and updated, the 2016 edition of NFPA 80: Standard for Fire Doors and Other Opening Protectives helps you ensure proper installation, inspection, testing, and maintenance of fire door assemblies, fire window assemblies, fire dampers, fabric fire safety curtains, and fire protective curtain assemblies.

    Referenced by NFPA 101®: Life Safety Code®, model building codes, and fire codes, NFPA 80 is vital to the fire protection of openings.

    Proper installation of openings in fire rated assemblies is critical to both occupant life safety and property protection -- and fire doors and fire windows are required to be inspected and tested annually to ensure they remain in proper working condition and can help confine a fire should it occur.

    New in the 2016 edition:

    • Expanded requirements for fire door labels help Authorities Having Jurisdiction (AHJs) and end users verify that the assembly or product is appropriate.
    • New section for the required marking of fire rated glazing offers better usability by promoting standardized requirements.
    • New chapter on fire protective curtain assemblies addresses new technology.
    • Additional guidance for use of oversized fire doors reflects industry needs.
    • Reorganized requirements for actuation devices for use with fire doors, fire shutters, and fire windows.
    • A new allowance to use specific products on doors exceeding maximum clearance under the bottom of the door explicitly allows a new category of products, where listed for this use.

    From fire doors and fire windows to fabric fire safety curtains and fire dampers, NFPA 80 covers it all.

    Doors and other opening protectives that are not installed and maintained in accordance with NFPA 80 are at risk for compromising the fire barrier. That's why staying up-to-code is essential for everyone involved in building fire safety -- from manufacturers to designers, engineers, contractors, AHJs, fire door inspectors, and building owners. (Softbound, 93 pp., 2016)

     

    Interested in other editions of NFPA 80? Use the drop down menu above to select the edition year you need.

  • Table of Contents (2016 Current Edition)

    NFPA® 80 Standard for Fire Doors and Other Opening Protectives, 2016 Edition

    Chapter 1 Administration
    1.1 Scope.
    1.2 Purpose.
    1.3 Retroactivity.
    1.4 Equivalency.
    Chapter 2 Referenced Publications
    2.1 General.
    2.2 NFPA Publications.
    2.3 Other Publications.
    2.4 References for Extracts in Mandatory Sections.
    Chapter 3 Definitions
    3.1 General.
    3.2 NFPA Official Definitions.
    3.3 General Definitions.
    Chapter 4 General Requirements
    4.1 General Limitations.
    4.2 Listed and Labeled Products.
    4.3 Classifications and Types of Doors.
    4.4 Glazing Material in Fire Doors.
    4.5 Fire Resistance–Rated Glazing in Doors and Windows.
    4.6 Classification of Hardware for Fire Doors.
    4.7 Actuation Devices for Fire Doors, Fire Shutters, and Fire Windows.
    4.8 Supporting Construction.
    Chapter 5 Inspection, Testing, and Maintenance
    5.1 General.
    5.2 Inspection and Testing.
    5.3 Retrofit Operators.
    5.4 Performance-Based Option.
    5.5 Maintenance.
    Chapter 6 Swinging Doors with Builders Hardware
    6.1 Doors.
    6.2 Supporting Construction.
    6.3 Openings.
    6.4 Assembly Components.
    6.5 Application, Installation, and Adjustment.
    Chapter 7 Swinging Doors with Fire Door Hardware
    7.1 Doors.
    7.2 Supporting Construction.
    7.3 Openings.
    7.4 Assembly Components.
    Chapter 8 Horizontally Sliding Doors
    8.1 Doors.
    8.2 Supporting Construction.
    8.3 Openings. (Reserved)
    8.4 Assembly Components.
    Chapter 9 Special-Purpose Horizontally Sliding Accordion or Folding Doors
    9.1 Doors.
    9.2 Supporting Construction.
    9.3 Clearances Around Openings.
    9.4 Assembly Components.
    Chapter 10 Vertically Sliding Fire Doors
    10.1 Doors.
    10.2 Supporting Construction.
    10.3 Clearances.
    10.4 Assembly Components.
    Chapter 11 Rolling Steel Doors
    11.1 Doors.
    11.2 Supporting Construction.
    11.3 Openings.
    11.4 Assembly Components.
    11.5 Weather Protection.
    Chapter 12 Fire Shutters
    12.1 Types.
    12.2 Requirements.
    12.3 Weather Protection.
    Chapter 13 Service Counter Fire Doors
    13.1 Doors.
    13.2 Supporting Construction.
    13.3 Counters.
    13.4 Automatic Closing.
    Chapter 14 Hoistway Doors for Elevators and Dumbwaiters
    14.1 Doors.
    14.2 Types of Doors.
    14.3 Hoistway Door Vision Panels.
    14.4 Door Operation.
    Chapter 15 Chute Doors
    15.1 Chute Discharge Doors.
    15.2 Chute Intake Doors.
    15.3 Limited-Access Gravity Chutes.
    15.4 Pneumatic Chute Intake Doors.
    Chapter 16 Access Doors
    16.1 Doors.
    16.2 Types of Doors.
    Chapter 17 Fire Windows
    17.1 Windows.
    17.2 Glazing Material.
    17.3 Types of Windows.
    17.4 Installation.
    17.5 Closing Devices.
    Chapter 18 Glass Block Assemblies
    18.1 General.
    18.2 Installation.
    Chapter 19 Installation, Testing, and Maintenance of Fire Dampers
    19.1 General.
    19.2 Installation.
    19.3 Operational Test.
    19.4 Acceptance Testing.
    19.5 Periodic Testing.
    19.6 Maintenance.
    Chapter 20 Fabric Fire Safety Curtains
    20.1 General.
    20.2 Fabric Fire Safety Curtain Components.
    20.3 Installation.
    20.4 Fire Safety Curtain Assemblies.
    20.5 Supporting Construction.
    20.6 Rigging and Lifting Equipment.
    20.7 Operation of the Fire Safety Curtain Assembly.
    20.8 Acceptance Testing.
    20.9 Care and Maintenance.
    Chapter 21 Fire Protective Curtain Assemblies
    21.1 General.
    21.2 Mounting of Fire Protective Curtain Assemblies.
    21.3 Assembly Components.
    21.4 Power Operators.
    21.5 Installation.
    21.6 Inspection, Testing, and Maintenance.
    21.7 Acceptance Testing.
    21.8 Closing Devices.
    21.9 Periodic Inspection and Testing.
    21.10 Maintenance.
    Annex A Explanatory Material
    Annex B Fire Doors: Protection of Conveyor Openings
    Annex C Illustration of Types of Fire Window Components
    Annex D Fire Door and Fire Window Classifications
    Annex E Surface Attachments to Swinging Door Faces
    Annex F Door Hardware Locations
    Annex G Types of Door Construction
    Annex H Special Purpose Doors
    Annex I Radiant Heat Transfer
    Annex J Performance-Based Option for the Inspection, Testing, and Maintenance of Fire Door Assemblies
    Annex K General Information About Fire Doors
    Annex L Informational References
  • NFPA eBooks and PDF's

    NFPA® eBooks and PDFs can be downloaded immediately after purchase for quick, easy access. For the best reading experience, NFPA recommends using the free NFPA eReader application, NFPA eLibrary.

    Download now.

    Google Play Store badge

    About the free NFPA eLibrary app
    The free NFPA eLibrary app gives you access to your NFPA eBooks and PDFs both online and offline. The app has tools to help you get your job done, search, highlight text, add bookmarks, or copy and paste text into your documents and presentations. Sign-in with your NFPA username and password. Access is immediate.

    Accessing
    Upon purchase of an NFPA eBook or PDF, you will be prompted with instructions for downloading and accessing.

  • What is a Redline PDF?

    NFPA®'s Redline PDF contains both the current NFPA document and a Redline version of the document which shows changes from the previous edition marked in color. With the Redline you can quickly spot changed sections and tell specifically what has been changed from the previous edition, saving time and confusion.

    • Changed sections are marked with a vertical rule.
    • Deleted material is shown in red strikethrough type.
    • New material appears in blue underscored type.

     

    Sample (NEC® 2014)

    411.2411.3 Definition. Low-Voltage Lighting Systems.

     

    (A) General. Lighting Ssystems Ooperating at 30 Volts- volts or  Less. A lighting system consisting less shall consist of an isolating power supply, the low-voltage luminaires, and associated equipment that are all identified for the use. The output circuits of the power supply are shall be rated for not more than 25 amperes and  operate at 30 volts (42.4 volts peak) or lessmaximum under all load conditions.

     

    (B) Class 2. Listed Class 2 lighting equipment shall be rated in conformance with Chapter 9, Table 11(A) or Table 11(B).

     

    411.3411.4 Listing Required. Lighting systems operating at 30 volts or less shall comply with 411.3(A)411.4(A) or 

    411.3(B).411.4(B). Class 2 power sources and lighting equipment connected to Class 2 power sources shall be llisted.

  • Also in NFPA 80: Standard for Fire Doors and Other Opening Protectives