NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection System

Available Discounts

 Members Save 10%

  •  
Save 15% with a Set!

  • Order now and save 15% on 2 or more formats.
Item #: NFPA_25
List Price: $0.00
2014 NFPA 25


2014 NFPA 25 Handbook

Prior Years Prior Editions of NFPA 25
Quantity:

Water-based fire sprinkler protection systems comprise the bulk of commercial and residential installations. Properly inspecting, testing, and maintaining these complex systems requires close attention to mechanical details and various important provisions.

The new 2014 NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems offers comprehensive guidance on maintaining suppression systems for optimum performance. Effective use of NFPA 25 reduces risk of death by 80% and average property loss by nearly 70%. In fact, 2013 NFPA 13 requires that installers leave a copy of NFPA 25 with property owners so that inspectors, building owners, and facility managers can maximize protection.

Inspection, testing, and maintenance regimes covered by NFPA 25 include evaluation techniques such as:

  • Fire sprinkler inspections
  • Valve status tests
  • Internal piping assessments
  • Fire pump operating tests
  • Fire pump flow tests
  • Forward-flow tests for back-flow preventers
  • Risk assessment and performance-based testing programs
  • Preparing preplanned impairment reports, hydrant flushing, and testing

Learn about the latest provisions in the new 2014 NFPA 25:

  • Updated fire pump operating test-frequency rules
  • New fuel-supply testing procedures for diesel-driven fire pumps
  • Modified definition of "sprinkler system" for consistency with NFPA 13
  • Clarification about inspecting the insides of sprinkler pipes
  • An expanded scope that includes water-mist systems
  • The addition of valve status testing to ensure water is reaching the sprinkler system

Ongoing water-based fire protection system maintenance is far less costly than having to replace entire systems. And ensuring function and performance of sprinkler systems is especially important for protection of life and property.

To stay compliant with NFPA 25 and meet the highest national standards of fire and electrical safety, order your copy today. (Softbound, 136 pp., 2014)

Editor: Matthew J. Klaus

ITM questions? The 2014 NFPA 25 Handbook has the answers you need to conduct efficient safety checks and avoid sprinkler failures.

Because errors or oversights in sprinkler upkeep could result in fire tragedies and fire loss, it's vital not only to work with the latest ITM requirements, but also to make sure you apply them correctly. And that's exactly what the comprehensive 2014 Water-Based Fire Protection Systems Handbook is designed to do.

This essential NFPA 25 companion strengthens your understanding of the intent behind rules and the function of the systems and components covered in the Standard so you can improve sprinkler reliability and increase equipment service life.

  • The complete 2014 NFPA 25: Inspection, Testing, and Maintenance of Water-Based Fire Protection Systemstext is included for convenient reference and enhanced by explanations and practical application advice.
  • Case studies provide examples of real-world sprinkler experience.
  • 100+ full-color photos, charts, illustrations, and other visuals clarify concepts.
  • Sample inspection, testing, and maintenance forms help in implementing your own procedures.
  • Updated FAQs highlight key topics.

NEW 2014 features include:

  • Step-by-step testing procedures provide an example of a correct and proven way to conduct a test.
  • ITM vs Design Evaluation feature presents specific examples and helps users determine whether or not something is within the scope of NFPA 25 (ITM) or out of scope (Design Evaluation).
  • Four new supplements expand your expertise -- Fire Pump Flow Test Analysis, Role of the AHJ, Inspection Roles and Responsibilities (Table), and Fire Pump Field Data Collection and Analysis.

Anyone who works with sprinklers -- from sprinkler contractors, service contract providers, facility managers, and building owners to engineers and designers, consultants, AHJs, insurance representatives and NFPA 13: Installation of Sprinkler System users -- needs the 2014 NFPA 25 Handbook to ensure water-based systems are up-to-code and ready to protect lives and property. (Hardbound, 690 pp., 2014)

NFPA® 25 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems 2014 Edition

Chapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Application
1.4 Units
Chapter 2 Referenced Publications
2.1 General
2.2 NFPA Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
3.4 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems Definitions
3.5 Valve Definitions
3.6 Water-Based Fire Protection System Definitions
3.7 ITM Task Frequencies
Chapter 4 General Requirements
4.1 Responsibility of Property Owner or Designated Representative
4.2 Manufacturer's Corrective Action
4.3 Records
4.4 Water Supply Status
4.5 Inspection
4.6 Testing
4.7 Performance-Based Programs
4.8 Maintenance
4.9 Safety
Chapter 5 Sprinkler Systems
5.1 General
5.2 Inspection
5.3 Testing
5.4 Maintenance
5.5 Component Action Requirements
Chapter 6 Standpipe and Hose Systems
6.1 General
6.2 Inspection
6.3 Testing
6.4 Maintenance
6.5 Component Action Requirements
Chapter 7 Private Fire Service Mains
7.1 General
7.2 Inspection and Corrective Action
7.3 Testing
7.4 Maintenance
7.5 Component Action Requirements
Chapter 8 Fire Pumps
8.1 General
8.2 Inspection
8.3 Testing
8.4 Reports
8.5 Maintenance
8.6 Component Replacement Testing Requirements
Chapter 9 Water Storage Tanks
9.1 General
9.2 Inspection
9.3 Testing
9.4 Maintenance
9.5 Automatic Tank Fill Valves
9.6 Component Action Requirements
Chapter 10 Water Spray Fixed Systems
10.1 General
10.2 Inspection and Maintenance Procedures
10.3 Operational Tests
10.4 Ultra-High-Speed Water Spray System (UHSWSS) Operational Tests
10.5 Component Action Requirements
Chapter 11 Foam-Water Sprinkler Systems
11.1 General
11.2 Inspection
11.3 Operational Tests
11.4 Maintenance
11.5 Component Action Requirements
Chapter 12 Water Mist Systems
12.1 Inspection and Testing.
12.2 Maintenance.
12.3 Training
Chapter 13 Valves, Valve Components, and Trim
13.1 General
13.2 General Provisions
13.3 Control Valves in Water-Based Fire Protection Systems
13.4 System Valves
13.5 Pressure-Reducing Valves and Relief Valves
13.6 Backflow Prevention Assemblies
13.7 Fire Department Connections
13.8 Component Testing Requirements
Chapter 14 Internal Piping Condition and Obstruction Investigation
14.1 General
14.2 Assessment of Internal Condition of Piping.
14.3 Obstruction Investigation and Prevention
14.4 Ice Obstruction
Chapter 15 Impairments
15.1 General
15.2 Impairment Coordinator
15.3 Tag Impairment System
15.4 Impaired Equipment
15.5 Preplanned Impairment Programs
15.6 Emergency Impairments
15.7 Restoring Systems to Service
Chapter 16 Special Requirements from Other NFPA Documents
16.1 General
16.2 Small Residential Board and Care Occupancies
Annex A Explanatory Material
Annex B Forms for Inspection, Testing, and Maintenance
Annex C Possible Causes of Pump Troubles
Annex D Obstruction Investigation
Annex E Hazard Evaluation Form
Annex F Informational References
Index

Contents

Preface

About the Contributors

About the Editor

PART ONE

NFPA® 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2014 Edition, with Commentary

1 Administration

1.1 Scope

1.2 Purpose

1.3 Application

1.4 Units

2 Referenced Publications

2.1 General

2.2 NFPA Publications

2.3 Other Publications

2.4 References for Extracts in Mandatory Sections

3 Definitions

3.1 General

3.2 NFPA Official Definitions

3.3 General Definitions

3.4 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems Definitions

3.5 Valve Definitions

3.6 Water-Based Fire Protection System Definitions

3.7 ITM Task Frequencies

4 General Requirements

4.1 Responsibility of Property Owner or Designated Representative

4.2 Manufacturer’s Corrective Action

4.3 Records

4.4 Water Supply Status

4.5 Inspection

4.6 Testing

4.7 Performanced-Based Programs

4.8 Maintenance

4.9 Safety

5 Sprinkler Systems

5.1 General

5.2 Inspection

5.3 Testing

5.4 Maintenance

5.5 Component Action Requirements

6 Standpipe and Hose Systems

6.1 General

6.2 Inspection

6.3 Testing

6.4 Maintenance

6.5 Component Action Requirements

7 Private Fire Service Mains

7.1 General

7.2 Inspection and Corrective Action

7.3 Testing

7.4 Maintenance

7.5 Component Action Requirements

8 Fire Pumps

8.1 General

8.2 Inspection

8.3 Testing

8.4 Reports

8.5 Maintenance

8.6 Component Replacement Testing Requirements

9 Water Storage Tanks

9.1 General

9.2 Inspection

9.3 Testing

9.4 Maintenance

9.5 Automatic Tank Fill Valves

9.6 Component Action Requirements

10 Water Spray Fixed Systems

10.1 General

10.2 Inspection and Maintenance Procedures

10.3 Operational Tests

10.4 Ultra-High-Speed Water Spray System (UHSWSS) Operational Tests

10.5 Component Action Requirements

11 Foam-Water Sprinkler Systems

11.1 General

11.2 Inspection

11.3 Operational Tests

11.4 Maintenance

11.5 Component Action Requirements

12 Water Mist Systems

12.1 Inspection and Testing

12.2 Maintenance

12.3 Training

13 Valves, Valve Components, and Trim

13.1 General

13.2 General Provisions

13.3 Control Valves in Water-Based Fire Protection Systems

13.4 System Valves

13.5 Pressure-Reducing Valves and Relief Valves

13.6 Backflow Prevention Assemblies

13.7 Fire Department Connections

13.8 Component Testing Requirements

14 Internal Piping Condition and Obstruction Investigation

14.1 General

14.2 Assessment of Internal Condition of Piping

14.3 Obstruction Investigation and Prevention

14.4 Ice Obstruction

15 Impairments

15.1 General

15.2 Impairment Coordinator

15.3 Tag Impairment System

15.4 Impaired Equipment

15.5 Preplanned Impairment Programs

15.6 Emergency Impairments

15.7 Restoring Systems to Service

16 Special Requirements from Other NFPA Documents

16.1 General

16.2 Small Residential Board and Care Occupancies

ANNEXES

A Explanatory Material

B Forms for Testing, Inspection, and Maintenance

C Possible Causes of Pump Troubles

D Obstruction Investigation

E Hazard Evaluation Form

F Informational References

PART TWO

Supplements

1 Microbiologically Influenced Corrosion in Fire Sprinkler Systems

2 Conducting Fire Pump Flow Tests

3 ITM Roles and Responsibilities

4 Role of the Inspector

5 Role of the Owner or Designated Representative

6 Role of the Authority Having Jurisdiction

7 Fire Pump Field Data Collection and Analysis

8 Technical/Substantive Changes from the 2011 Edition to the 2014 Edition of NFPA 25

Index

Important information about NFPA codes and standards available


NFPA® Handbooks are your 'Roadmap to the Codes' with insights and graphics that answer code questions. View these sample pages for a preview of the valuable information you'll access including complete code or standard text; explanatory commentary highlighted in a second color; hundreds of full-color photos, charts, tables and illustrations to clarify concepts; and much more.

  • The online version of this document is presented in RealRead. Questions about RealRead?
  • This document is designed to be viewed online only - There are no "print","save","cut and paste", or "search" options in the sample.
  • As a minimum Microsoft Internet Explorer 5.0 or Netscape 4.7 are required (for Mac, I.E. 5.0).
  • Cookies, JAVA Script, and JAVA Applet downloads must be enabled.

Preview NFPA 25: Water-Based Fire Protection Systems Handbook


NFPA’s Redline PDF contains both the current NFPA document and a Redline version of the document which shows changes from the previous edition marked in color. With the Redline you can quickly spot changed sections and tell specifically what has been changed from the previous edition, saving time and confusion.

  • · Changed sections are marked with a vertical rule.
  • · Deleted material is shown in red strikethrough type.
  • · New material appears in blue underscored type.

Sample (NFPA 10, 2010)

5.3.2.7* Wheeled fire extinguishers shall be considered for hazard protection where fulfillment of the following requirementsis necessary: in areas in which a fire risk assessment has shown the following:

(4) (1) High hazard areas are present.

(5) (2) Limited available personnel Limited available personnel are present, thereby requiring an extinguisher that has the following features:

(1) (a) High agent flow rates

(2) (b) Increased agent stream range

(3) (c) Increased agent capacity