Improve fire protection by maximizing system reliability and performance according to guidelines in the 2011 NFPA 12.

Trust the 2011 NFPA 12: Standard on Carbon Dioxide Extinguishing Systems for the latest rules for the installation and maintenance of carbon dioxide extinguishing systems. Coverage addresses total flooding systems, local application systems, hand hose line systems, standpipe systems, and mobile supplies.

Changes in this edition include:

  • Modified requirement for system operational tests ensures that notification devices are tested.
  • A new definition of ''fire watch'' was added to correlate with NFPA 1 and to provide clarification to what is meant when fire watch is required.
  • Editorial revisions were made to correct English to Metric unit conversions.

This Standard is essential for anyone whose job involves carbon dioxide fire extinguishing system equipment, including purchasers, installers, maintainers, designers, inspectors, consultants, engineers, and AHJs. (Softbound, 55 pp., 2011)

NFPA® 12 Standard on Carbon Dioxide Extinguishing Systems 2011 Edition

Chapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Retroactivity
1.4 Units
Chapter 2 Referenced Publications
2.1 General
2.2 NFPA Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
3.4 Special Definitions
Chapter 4 General Information
4.1 Restrictions for Normally Occupied Enclosures
4.2 Carbon Dioxide Use and Limitations
4.3 Personnel Safety
4.4 Specifications, Plans, and Approvals
4.5 Detection, Actuation, and Control
4.6 Carbon Dioxide Supply
4.7 Distribution Systems
4.8 Inspection, Maintenance, and Instruction
Chapter 5 Total Flooding Systems
5.1 General Information
5.2 Hazard Specifications
5.3 Carbon Dioxide Requirements for Surface Fires
5.4 Carbon Dioxide Requirements for Deep-Seated Fires
5.5 Distribution System
5.6 Venting Consideration
Chapter 6 Local Application Systems
6.1 General Information
6.2 Hazard Specifications
6.3 Carbon Dioxide Requirements
6.4 Rate-by-Area Method
6.5 Rate-by-Volume Method
6.6 Distribution System
Chapter 7 Hand Hose Line Systems
7.1 General Information
7.2 Hazard Specifications
7.3 Location and Spacing
7.4 Carbon Dioxide Requirements
7.5 Equipment Specifications
7.6 Training
Chapter 8 Standpipe Systems and Mobile Supply
8.1 General Information
8.2 Hazard Specifications
8.3 Standpipe Requirements
8.4 Mobile Supply Requirements
8.5 Training
Chapter 9 Marine Systems
9.1 Special Definitions
9.2 General
9.3 System Requirements
9.4 Inspection and Maintenance
Annex A Explanatory Material
Annex B Examples of Hazard Protection
Annex C Pipe and Orifice Size Determination
Annex D Total Flooding Systems
Annex E Surface Fires
Annex F Local Application Carbon Dioxide Systems
Annex G General Information on Carbon Dioxide
Annex H Informational References